Apply for loan
Login
Home
Tender search
earth fault relay
Search
TENDERS FOR earth fault relay
Following active tenders available for earth fault relay across India. View earth fault relay tender details and earth fault relay tender notices (NIT) for free. Download Tender documents for earth fault relay.
Transformers Tenders
Relays Tenders
Control Panel Tenders
Power Transformers Tenders
Capacitor Tenders
Battery Charger Tenders
Electrical Panels Tenders
Pump Controller Tenders
Apfc Panels Tenders
Energy Meter Tenders
Cable Trays Tenders
Amf Panel Tenders
Digital Multimeter Tenders
Current Transformers Tenders
Protection Relays Tenders
Pcc Panel Tenders
Vacuum Circuit Breaker Tenders
Voltage Relay Tenders
Under Voltage Relay Tenders
Earth Fault Relay Tenders
Filters
States
kerala (20)
tamil nadu (11)
uttar pradesh (11)
new delhi (8)
west bengal (8)
karnataka (7)
maharashtra (5)
jammu and kashmir (4)
punjab (4)
assam (3)
gujarat (3)
jharkhand (3)
uttarakhand (3)
odisha (2)
andhra pradesh (1)
bihar (1)
chhattisgarh (1)
lakshadweep (1)
madhya pradesh (1)
manipur (1)
rajasthan (1)
telangana (1)
andaman and nicobar (0)
arunachal pradesh (0)
dadra and nagar haveli (0)
daman and diu (0)
goa (0)
haryana (0)
himachal pradesh (0)
meghalaya (0)
mizoram (0)
multi state (0)
nagaland (0)
puducherry (0)
sikkim (0)
tripura (0)
Expected Price
Not Specified (12)
Less than 1 Lacs (2)
1 Lac to 10 Lac (18)
10 Lac to 1 Cr (41)
1 Cr to 10 Cr (11)
10 Cr to 100 Cr (13)
100 Cr + (3)
Bid Submission Dates
In 7 Days (41)
In 15 Days (66)
In a month (98)
1 - 20 of 100 Tenders
maharashtra
EARTH FAULT RELAY FOR
₹
Not Specified.
Expires on 02nd Aug, 2024
maharashtra
Item Description: earth fault relay for aux. convertor415/ 110v ckt. harmonic filter andcon torl circuit ( pos no. 89. 2. 89. 5. 89. 6 and 89. 7 ) 150 ma 43 ohm36/ 110 volt as per abb document no. hbvw 400011r0001 or latest and clw specn. no. clw/ es/ 3/ 0090 alt- c. [ warranty period: 30 m onths after the date of delivery ]
₹
Not Specified.
Expires on 02nd Aug, 2024
new delhi
Over Current & Earth Fault Numerical Relay, Transformer Differential Relay
₹
Not Specified.
Expires on 25th Jul, 2024
karnataka
Battery Earth Fault Relay of 110V DC as per Model No: FB1 110 of C & S Make along with Relay Case.
₹
Not Specified.
Expires on 14th Aug, 2024
karnataka
Earth fault Relay 110V DC ( Voltage Type ) EFRA- II. Pick Up Voltage 50 Volt DC, Aux. Voltage 110 Volt DC.
₹
Not Specified.
Expires on 22nd Jul, 2024
west bengal
MiCOM P741 Central Unit CU relay Type Numerical for Bus, Bar protection system, Numerical Relay MiCOM p442, Over, current and Earth Fault Relay MiCOM P141, Numerical, Transformer differential relay MiCOM P642, Relay ALSTOM MiCOM P743, Restricted Earth fault, Protection Relay MiCOM P643, Bay Control Unit AREVA, MICOM C264
as per datasheet item no 5
₹
Not Specified.
Expires on 08th Jul, 2024
uttar pradesh
WORK OF REPLACEMENT OF OLD ELECTRO MECHAMICAL OVER CURRENT, EARTH FAULT RELAY AND MASTER TRIP RELAYS OF 33KV FEEDER PANEL BY NEW NUMERICAL RELAYS AT 132KV S/ S MOHADDIPUR OLD, GORAKHPUR UNDER ETD- I, GORAKHPUR
preparation of panel front by cutting & adding new backelite shet/ms sheet for placement of housing of new numerical
relay
& master trip
relays
for proper mounting on panel front & covering
₹
2000 Lacs
Expires on 25th Jul, 2024
karnataka
Item Description: earth fault relay 110v dc ( voltage type ) efra- ii. pick up voltage 50 volt dc, aux. voltage 110 volt dc. spec/ drg-- english electric/ alstom type: spec- m 2yf328m ( vag/ vaa11 ) or exact eq uivalent. [ warranty period: 30 months after the date of delivery ]
₹
Not Specified.
Expires on 22nd Jul, 2024
west bengal
Earth fault Relay 110V DC ( Voltage Type ) EFRA- II. Pick Up Voltage 50 Volt DC, Aux. Voltage 110 Volt DC. ENGLISH ELECTRIC/ ALSTOM Type: SPEC- M 2YF328M ( VAG/ VAA11 ) OR EXACT EQUIVALENT.
₹
Not Specified.
Expires on 11th Jul, 2024
west bengal
Item Description: earth fault relay 110v dc ( voltage type ) efra- ii. pick up voltage 50 volt dc, aux. voltage 110 volt dc. english electric/ alstom type: spec- m 2yf328m ( vag/ vaa11 ) or exact equivalent. [ warranty period: 30 months after the date of delivery ]
₹
Not Specified.
Expires on 11th Jul, 2024
madhya pradesh
E4233028 Numerical Relays 01- SG4935609001- NUMERICAL, MULTI- FUNCTIONAL GENERATOR PROTECTION RELAY,_ IEC61850 COMPLIANT_ AS PER ANNEXURE- 1 ITEM 1., 02-, SG4935609010- NUMERICAL TRIPLE POLE THREE WINDING, TRANSFORMER PROTECTION RELAY_ IEC61850 COMPLIANT_, AS PER ANNEXURE- 1 ITEM 2., 03- SG4935609028-, NUMERICAL TRIPLE POLE FOUR WINDING TRANSFORMER, PROTECTION RELAY_ IEC61850 COMPLIANT AS PER, ANNEXURE- 1 ITEM 3, 04- SG4935609036- NUMERICAL, TRIPLE POLE FOUR WINDING TRANSFORMER PROTECTION, RELAY_ IEC61850 COMPLIANT AS PER ANNEXURE- 1 ITEM 4, 05- SG4935609044- NUMERICAL THREE PHASE OVER, CURRENT PROTECTION_ 50_ slash_ 51_ EARTH FAULT, PROTECTION RELAY_ IEC61850 COMPLIANT_ AS PER, ANNEXURE- 1 ITEM 5., 06- SG4935609060- NUMERICAL, THREE PHASE OVER CURRENT PROTECTION_ 50_ slash_ 51_, EARTH FAULT PROTECTION RELAY_ IEC61850 COMPLIANT_, AS PER ANNEXURE- 1 ITEM 6, 07- SG4935609079-, NUMERICAL FULL DISTANCE PROTECTION RELAY AS PER, ANNEXURE- 1 ITEM 7., 08- SG4935609087- NUMERICAL FULL, DISTANCE PROTECTION RELAY DIFFERENT MAKE AS PER, ANNEXURE- 1 ITEM 8, 09- SG4935609095- NUMERICAL FULL, DISTANCE and LINE DIFFERENTIAL PROTECTION RELAY,_ IEC61850 COMPLIANT_ AS PER ANNEXURE- 1 ITEM 9., 10-, SG4935609109- NUMERICAL FULL DISTANCE and LINE, DIFFERENTIAL PROTECTION RELAY_ IEC61850 COMPLIANT_, DIFFERENT MAKE AS PER ANNEXURE- 1 ITEM 10, 11-, SG4935609117- METROSIL AS PER ANNEXURE- 1 ITEM 11., 12- SG4935609125- RESISTOR AS PER ANNEXURE- 1 ITEM 12, 13- SG4935609133- TRIPLE POLE NUMERICAL LOW, IMPEDANCE TYPE HIGH SPEED CENTRALISED BUSBAR, PROTECTION RELAY FOR 11 BAYS AS PER ANNEXURE- 1, ITEM 13, 14- SG4935609141- TRIPLE POLE NUMERICAL LOW, PROTECTION RELAY FOR 7 BAYS AS PER ANNEXURE- 1 ITEM, 14, 15- SG4935609150- TRIPLE POLE NUMERICAL LOW, PROTECTION RELAY FOR 3 BAYS AS PER ANNEXURE- 1 ITEM, 15., 16- SG4935609052- EVALUATION UNIT AS PER, ANNEXURE- 1 ITEM 16.
11-sg4935609117-metrosil as per annexure -1 item 11.
₹
Not Specified.
Expires on 06th Jul, 2024
maharashtra
Tender for Providing & fixing of Non Directional Over current/ Earth fault and Differential Numerical Relays to be used in 33/ 22/ 11 kV Control & Relay Panels for Lines and Power Transformer ( Ashida, Avona, JVS & any other …….. under Hingoli Circle
₹
2000 Lacs
Expires on 09th Jul, 2024
uttar pradesh
Repairing of 02 No 33 KV VCB 33 KV C and R Pannel, damaged over current/ earth fault and master trip relay on many Sub Station in the jurisdiction of EDD Behat under ETD I Saharanpur
providing fixing oti/wti temp meter
₹
2000 Lacs
Expires on 05th Jul, 2024
uttar pradesh
Repairing of 02 No 33 KV VCB 33 KV CT CandR Pannel damaged over current/ earth fault and master trip relay on many sub station In the jurisdiction of ETL Deoband uner ETD I SRE
providing fixing oti/wti temp meter
₹
2000 Lacs
Expires on 05th Jul, 2024
karnataka
CRM Kit up to 200A, HT Breaker Time Testing Kit, DC Earth Fault Locator, Leakage Current Analyser of Surge Arrestor, ELCB Tester, Industrial True RMS Multimeter, AC DC Clamp metre 1000a with iflex, digital earth tester, ht insulation tester up to 10. 0kv, lt insulation tester up to 1. 0kv, dc mili amp process clamp metre, 4 to 20mA, Loop Calibrator, Digital Motor Checker EMC 22, Automatic Relay testing Kit, Power Quality Analyser
ac dc clamp meter 1000a with iflex
₹
Not Specified.
Expires on 12th Jul, 2024
west bengal
Item Description: submersible pump automation star delta starter capacity 25hp 415v, ac with minilac make micr oprocessor based pump automation system ' ' m- commander ' ' with 24hrs. sequence timer for pump controlling a utomatic with 12v dc battery, protection consisting single phase preventer, u/ o voltage, overload relay, dry r un, lock rotor, earth fault, water level guard, contactors, voltmeter, ammeter and other accessories, suitable b usbar complete set. [ warranty period: 30 months after the date of delivery ]
₹
Not Specified.
Expires on 12th Jul, 2024
uttarakhand
Installation of 46 nos. MCCB on Transformers in Sh. Kedarnath Dham on Turnkey Basis Under EDD, Rudraprayag.
ms clamp bottom side for stp sp-23/ sp-55
₹
3425 Lacs
Expires on 08th Jul, 2024
andhra pradesh
Testing of Protection relays and meters at Captive Power Plant, HWP ( Manuguru ) during MTA- 2024
generator rotor
earth
fault
relay
state i
₹
1602 Lacs
Expires on 06th Jul, 2024
odisha
Testing Service for On- Board/ Commissioned Equipment/ Instrument related to Plant
3.3kv
₹
6212 Lacs
Expires on 12th Jul, 2024
jharkhand
Partial Repair of 3. 3KV Neutral Grounding Resistor with Monitoring and Protection relay 11KV/ 3. 3KV Transformer and 2 No of Earth Pit Making for NGR at BGR Camp Kuya OCP.
electronic
earth
fault
relay
with time lag characteristic having test reset facility & trip indication arrangement
₹
8690 Thousand
Expires on 09th Jul, 2024
Previous
1
2
3
4
5
Next